Flowserve BK 45 User Manual

Page 5

Advertising
background image

5

Function

During start-up of the plant the steam trap is completely open. Cold condensate and air are dis-

charged. As the temperature rises, the bimetallic plates deflect, drawing the stage nozzle towards the

closed position.
Just before the condensate reaches saturated steam temperature the orifice will be shut off tight.

The thermodynamic effect of the stage nozzle chamber assists in the closing process.
The steam trap provides automatic air-venting at start-up and during operation of the plant and can

also be used for thermal air-venting.

Description

Thermostatic/thermodynamic steam trap with corrosion resistant Thermovit

®

regulator (bimetallic

plates) able to withstand waterhammer. With internal strainer and integral non-return valve action.

Asbestos-free body gasket (graphite/CrNi).
The standard version discharges the condensate with virutally no banking-up, the version “U” with

approx. 0 K undercooling.

Scope of supply

BK 45:

 Steam trap BK 45

 Installation manual

BK 46:

 Steam trap BK 46

 Installation manual

BK 45U:

 Steam trap BK 45U

 Installation manual

Explanatory Notes

Advertising
This manual is related to the following products: