Installation – Flowserve BK 45 User Manual

Page 9

Advertising
background image

9

. Make sure that the flow arrow on the trap body matches the direction of flow of the steam.
. Consider space required for servicing the trap. When the trap is installed a minimum withdrawal

space for servicing is required for removing trap parts (see

Design, Component Parts BK...).

. Remove plastic plugs. They are only used as transit protection.
4. Clean end connections.
5. Install steam trap with releasable end connections (e. g. flanges).
5. For equipment with socket-weld ends or butt-weld ends: Apply arc welding processes  and 4

according to ISO 406 (or equivalent standard).

Installation instructions

When installing the steam trap make sure that the flow arrow on the trap body matches the direction

of flow of the steam. Preferred installation of the steam trap with the strainer insert hanging down-

wards to facilitate cleaning. Other installation orientations are possible, please consult the factory with

installation details. We recommend not to insulate the steam trap.

BK 45, BK 45U, BK 46

Installation

Danger

The equipment is under pressure and hot during operation. Risk of severe burns and

injuries to the whole body.
Installation and maintenance work should only be carried out when the system is depres-

surized (0 bar) and cold (0 °C).
The equipment must be isolated and vented from both upstream and downstream pres-

sure before installation or maintenance work is performed.
Sharp edges on internals present a danger of cuts to hands.

Always wear industrial gloves when servicing the equipment.

Attention

Welded trap installation should only be performed by qualified welders (certified ac-

cording to DIN EN 87 or equivalent).

Advertising
This manual is related to the following products: