5. The battery pack should be visible on the lower

end of the transmitter assembly. Carefully
disconnect the battery pack connector.
Remove the nuts holding the battery bracket in
place and remove the bracket. Remove the
battery pack.


Figure 6: SELD-103 unit battery with external
housing removed

Figure 7: SELD-103 unit with battery bracket
removed and battery pack partially removed

6. Install new battery pack (part number S1-

1043). Reinstall battery bracket and nuts,
reconnect battery pack connector.

7. Install tube back onto unit and tighten set

screw to no more than 0.9 Nm (8 lb.-in US).

8. Reinstall SELD-103 unit in the field.
9. Reconnect sensor cable(s).
10. Install magnetic set screw into the base of the

unit.

11. Install any applicable accessories on the

SELD-103 unit.

12. Dispose of battery pack in accordance with

instructions in section 2.5 Disposal Instructions.

5 CUSTOM CONFIGURATION
PROGRAMMING

This section is optional. As long as your

specific application was communicated to the
factory prior to shipment, the SELD-103 unit is pre-
configured for your specific use.

Errors in programming

configuration can render the SELD-103 unit
inoperable, proceed with caution. Flowserve is
not liable for any damage caused by user
configuration errors.

For instructions on how to change software
configuration options on the SELD-103 unit, refer to
the PSP software user instructions. The list below
provides an overview of the functions that can be
performed using this software utility:

-

Reading & saving SELD-103 configuration

-

View & modify SELD-103 transmission
intervals

-

Setting the time on the SELD-103

-

Calibration of individual sensors on SELD-
103 unit

-

Read live data from sensors on the SELD-
103 unit

-

Turn specific SELD-103 sensor channels
on or off

For instructions on how to perform software options
on the VB-103-TAM unit, refer to the IPS Dock user
instructions. The list below provides an overview of
the functions that can be performed using the IPS
Dock and appropriate software utility:

-

Reading & saving VB-103-TAM log data

-

Clearing the log from the VB-103-TAM

-

Setting the time on the VB-103-TAM

-

Changing the data logging interval on the
VB-103-TAM

6 INSTALLATION

Always wear appropriate personal

protective equipment during the installation of
SELD-103 units.

6.1 Tools required

Allen Wrenches

(1/8” and 3/16”)

Tools required to install the various
mounting configurations are conditional
based on the type of mounting and location

Phillips head torque screw driver

Nuts holding
battery bracket

Battery bracket