Maximum input amps, Energy star compliance, Table 9 – Dell R510 User Manual

Page 38: Operating/non-operating (storage) requirements, 4 maximum input amps, 5 energy star compliance

Advertising
background image

Dell

PowerEdge R510 Technical Guide

38

Table 9.

Operating/Non-Operating (Storage) Requirements

Operating Requirements

Non-Operating Requirements

Temperature Ranges
(For Altitude ≤900 m or 2952.75 ft)

10 to 35 °C

(50 to 95 °F)

-40 to 65 °C

(-40 to 149 °F)

Temperature Ranges
(For Altitude > 900 m or 2952.75 ft)

10 to Note

1

°C

(50 to Note

2

°F)

Temperature Gradient
Maximum per 60 Min.

10 °C

20 °C

Humidity Percent Ranges
Noncondensing

20 to 80 %

*

(*Max Wet bulb temperature= 29 °C)

5 to 95 %

+

(

+

Max Wet bulb temperature=

38 °C)

Humidity Gradient
Maximum per 60 Min.

10 %

10 %

Altitude Ranges

Low Limits

-50 feet
(-15.2 meters)

-50 feet
(-15.2 meters)

High Limits

10,000 feet
(3048 meters)

35,000 feet
(10,668 meters)

Use the following formulas to calculate the maximum operating temperature (in °C) for a given altitude.
Use the first formula if the altitude is stated in meters and the second formula if the altitude is stated in
feet.

C

25

.

984

2952.75

-

ft)

n

Altitude(i

Maximum

35

C

300

900

-

meters)

n

Altitude(i

Maximum

35

or

Use the following formulas to calculate the maximum operating temperature (in °F) for a given altitude. Use
the first formula if the altitude is stated in meters and the second formula if the altitude is stated in feet.

F

32

25

.

984

8

.

1

2952.75

-

ft)

n

Altitude(i

Maximum

95

F

32

300

8

.

1

900

-

meters)

n

Altitude(i

Maximum

95

or

5.4 Maximum Input Amps

The power supply is equipped with automatic input voltage detection. Maximum input amps are as
follows:

Non-redundant power supply: 7.5 - 3.8 A at 100-240 VAC, 50/60 Hz

Redundant power supply: 10.8 - 5 A at 100-240 VAC, 50/60 Hz

5.5 Energy Star Compliance

See the

ENERGY STAR Compliance results

on Dell.com.

Advertising