Primary/redundant router application, Datacom systems inc – Datacom Systems SS series SPAN User Manual

Page 23

Advertising
background image

Datacom Systems Inc

SPAN and Multi-Link Aggregators/Regenerators • USERguide

23

Figure 15 - VS-1022BT-BT Hardware Installation

Primary/Redundant Router Application —

shown in Figure

15, focuses on monitoring and analyzis of the SPAN output of a Primary and
Redundant network aggregated into one single stream of data. This VS-1022SX-SX is
similiar to other VERSAstream

SPAN series installations:

connecting the second power supply to a different external power source circuit
than the first power supply eliminates power as a single point of failure. The
POWER 1 and 2 LEDs illuminate indicating power 1 and 2, respectively, are on.
Either LED not illuminated indicates a defective power source and immediate
replacement is required to insure redundant power integrity.

2. Connect one network device duplex-SC plug to the FIBERtap

duplex-SC B

OUT and A IN connector.

3. Connect the other network device duplex-SC plug to the FIBERtap

duplex-SC

A OUT and B IN connector.

4. Using either a DRL490-2m (62.5 micron for SX) Cable or a DRL491-2m (9

micron for LX) Cable, connect the FIBERtap

duplex-SC A OUT and B OUT

connector to both of the VERSAstream

duplex-LC NETWORK ports. The LED

associated with each NETWORK duplex-LC jack is solid green indicating light sig-
nal has been detected on the Rx NETWORK ports.

5. Connect analysis devices to the VERSAstream

duplex-LC MONITOR ports. Two

DRL494–2m cables are provided to connect analysis SC ports to the duplex-LC MON-
ITOR
ports. The LED associated with each MONITOR duplex-LC jack is solid green
indicating when light signal has been detected on the respective Rx MONITOR port.

Advertising