3 tone open numbers, 4 input switch – DoorKing PC Compatible Multi-Door Access Controller 1838 User Manual

Page 28

Advertising
background image

3.3.3

Tone Open Numbers

These steps will program the tone open numbers for relays 1 and 2. You will need to enter a four-
digit number (see chart below) to set the relay functions. If a function is not desired, enter # in place
of a number. For example, if you want the relay to have a momentary activation function only, and
you want the relay to activate when the number 9 is pressed on a touch-tone phone after calling the
system, enter 9 # # # in step 4. Do not duplicate tone open numbers, i.e., don’t set relay 1 and 2
tone-open numbers all to 9. If Tracker expansion boards are connected to the system, there is no
need to set a momentary open tone open number for the tracker control relay(s). However, you may
want to set HOLD and DEACTIVATE tone numbers, which will allow management to have a function
to automatically unlock all doors/gates controlled by a Tracker board (refer to 4.2.2).

Factory setting is: Relay 1 = 9876, Relay 2 = 5432.

1. Press

* 0 5 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2. Press

1 * to set relay 1 or 2 * to set relay 2 tone numbers.

3.

Enter the four-digit tone open number code _ _ _ _ then press * (beep).

4.

Repeat steps 2 and 3 to set the other relay tone open numbers.

5. Press

0 # TOGETHER to end this programming step (beeeeeep).

NUMBER FUNCTION

1

st

Digit

Momentary activation. Relay will activate for the programmed strike time (3.3.1).

2

nd

Digit

Relay hold. Relay will activate and remain activated until commanded to release.

3

rd

Digit

Relay release. Deactivates the relay hold command.

4

th

Digit

Relay hold 1-hour. Relay will activate for 1-hour and then will automatically deactivate itself.

3.3.4 Input

Switch

This programming sequence sets what relay(s) will activate when the input (postal) switch input is
activated on the access control system. The system can be programmed so that only one relay will
activate, or any combination of relays will activate. To cause a relay to activate, enter a 1 in it's
respective character slot, or enter a zero to not activate the relay. Any combination of 1's or 0's is
permissible. For example, entering 010 in step 3 will cause only relay 1 to activate. Entering 011 will
cause both relay 1 and relay 2 to activate.

Factory setting = 010.

NOTE: Although you are setting the input switch activation for two relays only, you must
enter a three-digit code in step 2. Always use 0 as the first digit.

1. Press

* 5 0 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the three-digit (1's or 0's only) postal relay code _ _ _ then press * (beep).

3. Press

0 # TOGETHER to end this programming step (beeeeeep).

Page

28

1838-065-L-3-10

Advertising