5.1.4

Elevator Board / Floor Hardware Test

This testing sequence will allow you to check activation of individual relays on the elevator control
board(s) and will confirm communication between the 1838 circuit board and the elevator control
board(s).

1. Press

* 7 7 and enter the four-digit master code _ _ _ _ (beep).

2. Enter the elevator shaft number _ (1, 2, 3 or 4) then press * (beep).

3. Enter the two-digit floor number _ _ , then press * (beep).

4. The relay LED on the elevator control board that represents the floor number entered will

turn ON for approximately 1 second.

5. To check other floor relays, repeat steps 2 and 3.

6. When complete with the testing, press 0 # TOGETHER to end this testing sequence.

NOTE: This program test sequence will automatically end itself if no keypad inputs are
detected after approximately 30 seconds.

Refer to the Elevator Control board installation manual for more information on trouble
shooting the elevator control boards
.

1838-065-L-3-10

Page

45

Advertising