Ht2000 water muffler pump cable -8, Pump discharge hose check valve (optional) -8, Ht2000 water muffler pump cable – Hypertherm HT2000 Water Muffler User Manual

Page 33: Pump discharge hose check valve (optional)

Advertising
background image

STANDARD COMPONENTS

Page 4-8

HT2000/MAX200

Water Muffler

Instruction Manual

HT2000 WATER MUFFLER PUMP CABLE

Stock Nos. - 023866 (50 ft) / 023867 (75 ft) / 023868 (100 ft)

Stock

Number

Description

Item

Quantity

008195

Caclp: CPC Size 11

1

1

008205

Pin: 18-16 AWG Type III

2

3

008211

Plug Shell: CPC 11-4Rvs Sex

3

1

047190

Cord: 18-3 SV Rbr UL/CSA

4

50/75 or
100 ft

PUMP DISCHARGE HOSE CHECK VALVE (OPTIONAL)*

Stock

Number

Description

Quantity

034156

Valve, check

1

015052

Gland, hose 3/4 NPT x #12 straight

2

015234

Clamp, hose 3/4 to 1-3/4 inch

2

* Refer to Section 2,

Installation

for pump discharge hose water recovery checkout

and check valve installation information.

Figure 4-3 HT2000 Water Muffler Pump Cable - PS to WM

1

4

2

From 1X10 To WM Pump

Color

Function

Pin

Contactor

2

Coil

Black

Water Muffler Coil

4

AC Neut.

White

AC Neutral

3

Ground

Green

Ground

3

1-95

1X10

Advertising