SPECIFICATIONS

1-2

HT4400 with Titan Gas Panel

Instruction Manual

0

System Requirements

Gas Requirements:

Plasma Gas Types

Oxygen, Nitrogen

Shield Gas Types

Air; Nitrogen

Gas Quality:

Oxygen

99.5% pure (liquid gas recommended)

Nitrogen

99.995% pure (liquid gas recommended)

Air

99.995% pure (liquid gas recommended)

Maximum Gas Flow Rates and Inlet Pressures:

Oxygen

140 scfh (3965 sclh) @ 120 psi +/- 10 psi (8.3 bar +/- 0.7 bar)

Nitrogen

250 scfh (7080 sclh) @ 120 psi +/- 10 psi (8.3 bar +/- 0.7 bar)

Air

250 scfh (5664 sclh) @ 120 psi +/- 10 psi (8.3 bar +/- 0.7 bar)