Turn gases on, Turn power supply on and adjust current & voltage – Hypertherm HT4400 Plasma Arc Cutting System Gas Panel User Manual

Page 24

Advertising
background image

OPERATION

3-8

HT4400 with Titan Gas Panel

Instruction Manual

0

2. Turn Gases On

1. Turn the supply gases on.

2. Set S1 toggle switch on the gas panel to plasma gas O

2

, or

N

2

.

3. Set the Gas Select 1 lever on the gas panel to the proper

plasma gas.

4. Set the Gas Select 2 lever on the gas panel to the proper

shield gas. Note: If the shield gas is a mixture, set Gas
Select 2 to the non-plasma portion of the mixture.(e.g., If the
plasma gas is O

2

and the shield gas is Air, set Gas Select 2

switch to Air.)

5. Set the Valve Select thumb-wheel switch (S2) to Run.

Note:

See the Cut Charts (manual 803580) to set the plasma
and shield gas pressures.

3. Turn Power Supply On and Adjust Current & Voltage

1. Turn the main disconnect switch ON.

2. Turn on the power supply by positioning the CONTROL

POWER circuit breaker on the rear of the power supply to the
UP position. The system will automatically purge gases and
then display OK in the gas panel status display window.

3. Set the current from the machine computer interface or the

remote current control panel. Set the voltage from the
machine computer interface or torch-height control system.
Select the arc current and arc voltage numbers from the Cut
Charts
for the type and thickness of metal to cut.