Hypertherm HT4400 Plasma Arc Cutting System Gas Panel User Manual

Page 26

Advertising
background image

OPERATION

3-10

HT4400 with Titan Gas Panel

Instruction Manual

0

5. Verify Test Preflow

1. Set the Valve Select thumb-wheel switch (S2) to Test

Preflow.

2. Observe pressure readings on PG1 (plasma) and PG2

(shield). Verify that the readings are within +/- 3.0 psi (0.21
bar) of the PG1 and PG2 Test Preflow Verify rates specified
in the Cut Charts.

3. If readings are not within +/- 3.0 psi (0.21 bar), repeat the

preflow gas adjustments of steps 4.

6. Verify Test Cutflow

1. Set the Valve Select thumb-wheel switch (S2) to Test

Cutflow.

2. Observe pressure readings on PG1 (plasma) and PG2

(shield). Verify that the readings are within +/- 3.0 psi (0.21
bar) of the PG1 and PG2 Test Cutflow Verify rates specified
in the Cut Charts.

3. If readings are not within +/- 3.0 psi (0.21 bar), repeat the

cutflow gas adjustments of steps 4.

PG2

PG1

Valve Select

S2

7. Begin Cutting

Note:

If you have changed consumable parts or if the power supply has been off for more than 1 hour, purge gas
lines by leaving the system in Test Cutflow for one minute.

1. Set any additional cutting parameters as outlined in the Cut Charts (manual 803580).

2. Set Valve Select switch to Run after the test preflow and test cutflow rates have been verified.

3. The system is now ready to operate. Press the START command from the machine interface to begin the

cutting sequence.

Advertising