INSTALLATION

HT4400 with Titan Gas Panel

Instruction Manual

2-3

0

Post-Installation

HT4400 Initial Startup

After installation is complete, perform the following procedure to ensure the proper performance of the
HT4400 system before moving on to the Operation section of this manual. The gas panel will display error code
FS (flow switch error) on initial startup until: all air is out of the torch coolant loop; the reservoir in the water
cooler has an adequate supply of fluid. Follow the procedure below to satisfy the flow switch.

1. Verify that all installation requirements are met and that all

connections are made as outlined in this section and the
Installation section of manual 803580.

2. Verify that consumables are installed properly in the torch

(see Daily Startup in the Operation section, if necessary).

3. Verify that the torch coolant has been added to the water

cooler (see Installation section of manual 803580).

4. Position the valve select switch (S2) on the gas panel to

either Leak Test 1 or Leak Test 2.

5. Switch the Control Power switch on the power supply

ON (I).

6. Allow coolant to flow through the system. If the coolant is

flowing properly, propellers on the flow switch (FS1) will be
spinning rapidly.

Note: When propellers are spinning, the individual paddles

cannot be seen.

If coolant stops flowing and FS is still displayed on the gas
panel, turn valve select switch to RUN, and then back to
Leak Test 1 or Leak Test 2. This action allows the pump to
run for 30 seconds. Check coolant level.

7. After 5 minutes, switch the Control Power switch on the

power supply OFF (O).

8. Position the valve select switch (S2) on the gas panel to

RUN.

9. Switch Control Power switch on the power supply ON (I).

The coolant pump should continue to run and OK should
be displayed on the gas panel status display.

If FS or any other error code is displayed on the gas panel
other than OK, the system has a problem that needs to be
fixed before daily operations can begin. See Section 5,
Maintenance, of manual 803580 to troubleshoot.

Flow switch (FS1)

propellers

Status Display

Valve Select

(S2)

Check coolant
level