Inspecting and replacing consumables -9, Correct alignment of consumables -9, Powermax – Hypertherm Powermax190c Operator Manual User Manual
Page 38: Inspecting and replacing consumables

OPERATION
0
powermax
190c
Operator Manual
4-9
Inspecting and Replacing Consumables
Part
Verify
Action if defective
Shield
• Center hole is round.
Replace
• Side holes not blocked
Replace
Shielded
• Threads are undamaged
Replace
Cap
• Internal o-ring is in place and
Replace
undamaged
Torch O-ring
• No damage or wear
Replace
• Lubricated
Apply a thin film of silicone lubricant
Swirl Ring
• No damage or wear
Replace
• Side holes not blocked
Replace
• O-ring inside of front opening
Replace
is undamaged
Electrode
• Center surface not pitted more
Replace
than 1/16" (1.5 mm) deep
Nozzle
• Center hole is round.
Replace
• Side holes not blocked
Replace
Cap
• O-ring inside of front opening
Replace
is undamaged
Correct Alignment of
Consumables
Check the torch safety switch: Listen
for a “click” when the cap is replaced
on the torch.
Note:
Hand-tighten only
Cap
Cap