MAINTENANCE/PARTS

2

powermax

190c

Operator Manual

5-3

Basic Troubleshooting

1.1 Clean or replace worn consumables as

necessary.

1.2 Check for proper installation of swirl ring.

1.3 Check for proper input voltage. Check

that the power cord/extension cord is not
under size per Section 3.

1.4 Check that the work clamp is connected

to the workpiece.

1.5 Be certain that the torch tip is in close

contact with the workpiece. The pilot arc
will extinguish after 5 seconds if arc
transfer is not established.

1. No pilot arc; difficulty in establishing an

arc, difficulty in achieving arc transfer.

2.1 Place the Power switch to On (I)

2.2 Plug in the power cord.

2.3 Check line disconnect fuses and replace if

needed or reset circuit breakers.

2. No cutting output; POWER ON LED

extinguished, FAULT LED extinguished;
fan not running

3.1 Check that the work clamp is connected.

3.2 Clean or replace worn consumables as

necessary.

3.3 Over-heated compressor see Solution 4.2.

3. No cutting output; POWER ON illuminated;

FAULT LED extinguished; fan running

4.1 Check that all torch consumable parts are

in place and that the retaining cap is tight.
In this fault condition, the power supply
must be turned off and then turned on
before operation can begin.

4.2 Thermostat in power supply may be open

(overheating). Allow the fan to run; the
thermostat closes when the unit has
cooled (see Section 4, Duty Cycle and
Overheating
).

4.3 Input voltage not within specification (120

VAC +/- 20% or 230 VAC +/- 20%). In this
fault condition, the power supply must be
turned off and then turned on before
operation can begin.

4.4 Refer to Service Manual IM-366 (803660)

for more detailed troubleshooting.

4. FAULT LED illuminated

Problem

Solution