Hypertherm SensorOHC User Manual

Page 9

Advertising
background image

Section 1: Overview

5


Hardware Specifications

Main Power Supply:

24 Vdc +/- 10%, 50/60 Hz


Compatible Lifter Motors:

DC shunt motor 24Vdc, 2 Amps to 6 Amps


Operating Temperature:

0 to +50 deg C


Control Range:

Linear 0.1 inch to 1.0 inch (2.5 to 25 mm)

(standard sensor & cable)

Height Measuring Technology:

Capacitive Ring with Coax Cable


Accuracy:

0.01 inch (0.25 mm) w/ representative Lifter

(dependent on lifter mechanics)

HF Coax Cable:

500 mm to 1500 mm (1000 mm standard)


Standard Sensor:

Stainless Steel Ring 100 mm outer & 50 mm inner
diameters. Can be calibrated for others


Dimensions:

8.50”

(216mm) W x 4.21” (107mm) D x 4.02” (102mm) H


Control Type:

Digital Micro Processor based


Motor Output:

Full “H” Bridge PWM with current sensing


Control Interface:

Optically Isolated I/O on “D” connectors


Outputs: Digital

In-Position

Output

Digital

Error

Output

Digital

Plate

Contact

Output


Inputs:

Digital

Manual/Auto

Select

Digital Manual Up

Digital Manual Down

Digital

Upper

Limit

Switch

Digital

Lower

Limit

Switch

Digital

Second

Height

Select

Remote

Height

Set-point

Pot

Second

Height

Set-point

Pot


Front

Panel

Indicators

green

Power

yellow

Upper Limit Switch

green

In

Position

yellow

Lower

Limit

Switch

red

Attention/Error

Code

Advertising