Owner’s manual, Specifications, Accessory – Desa B600D User Manual

Page 13: Wiring diagram, Maintenance kits, Technical service, Fuel pressure gage m4574

Advertising
background image

13

099507

OWNER’S MANUAL

SPECIFICATIONS

350,000 Btu/Hr

600,000 Btu/Hr

Output Rating (Btu/Hr)

350,000

600,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity (U.S. Gallons)

30

36

Fuel Consumption (Gallons Per Hr)

2.5

4

Electric Requirements

120V/60 Hz

120V/60 Hz

Amperage (Normal Run)

7.1

11

Motor RPM

1725

1725

Fuel Pump Pressure (PSI)

100

110

Spark Plug Gap

.075"

.075"

Weight (approx. lbs.) Dry

180

285

With Full Fuel Tank

390

550

ACCESSORY

Purchase this heater accessory from your
nearest dealer or service center. If they can-
not supply this accessory, either contact
your nearest Parts Central or DESA
International's Parts Department at 1-800-
972-7879 for information. Parts Centrals
are listed in the Authorized Service Center
booklet supplied with heater. You can also
write to the address listed on the back page
of this manual.

WIRING DIAGRAM

1

3

2

FAN

SWITCH

7

5

B

A

MOTOR

RELAY

WHITE

RED

ORANGE

ORANGE

RED

BLACK

WHITE

BLACK

WHITE

BLUE

BLUE

WHITE

BLACK

BLACK

THERMOSTAT

B

R

FLAME-OUT

CONTROL

RESET

BUTTON

RED

YELLOW

YELLOW

RED

WHITE

SOLENOID

VALVE

WHITE

TERMINAL

BOARD

TERMINAL

BOARD

ELECTRONIC

IGNITOR

WHITE

SPARK

PLUG

PHOTOCELL

BLACK

WHITE

GREEN

YELLOW

WHITE

PLUG

120V
60Hz

Figure 17 - Wiring Diagram

Kit

Part Number

Flame-Out Control

HA3003

Spark Plug

HA3012

MAINTENANCE
KITS

FUEL PRESSURE GAGE
M4574

Special tool to check fuel pump pressure

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.

You can also visit DESA International’s
Technical Services web site at

www.desatech.com.

TECHNICAL
SERVICE

Advertising
This manual is related to the following products: