Preventative maintenance schedule – Desa B600D User Manual

Page 6

Advertising
background image

6

099507

HIGH PRESSURE PORTABLE FORCED AIR
HEATER 350,000 AND 600,000 BTU/HR

PREVENTATIVE
MAINTENANCE
SCHEDULE

Item

Fuel tank

Filler neck screen

Fuel filter assembly (Fuel tank)

Fuel filter lines

Fuel filter (Pump)

Spark plug

Fan blades and air deflectors

Air passages around burner head

Motor

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

How To

See Storing, Transporting, or Shipping,
page 5

Lift out of fuel tank and rinse with clean
kerosene

See Fuel Filters, page 12

See Fuel Lines, Page 12

See Fuel Filters, page 12

See Spark Plug, page 10

See Fan Blades and Air Deflectors, page 10

Remove debris and trash with a clean, soft cloth

How Often

Flush every 150-200 hours of operation or
as needed

Check for particles in fuel when filling fuel
tank. Clean when dirty

Clean twice a heating season or replace as
needed

Check and tighten loose connections occa-
sionally

Clean fuel filter element every 250 hours

Clean and regap every 300 hours of opera-
tion or replace as needed

Clean each season or as needed

Check each season for dirt and debris

Not required, permanently lubricated

Advertising
This manual is related to the following products: