MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Lighting

Instructions, page 19.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow steps 9 through

11 under Lighting Instructions, page 20.

OPERATING HEATER

Continued

OPTIONAL HAND-HELD

REMOTE OPERATION

Note:

HRC201 Hand-Held Remote Control Kit

is included with CHL3924NR/PR models only.

Hand-held remote control accessories must

be purchased separately for all other models

(see Accessories, page 34). Follow instructions

included with the remote control.

NOTICE: you must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions on page 19.

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere

between HI and LO. Slide the selector switch to

the REMOTE position (see Figure 33). Note:

The burner may light if hand-held remote was

on when selector switch was last turned off.

You can now turn the burner on and off with

the hand-held remote control unit.
IMPORTANT:

Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

ON/OFF SERIES (MODEL HRC101)

Hold the control button on the hand-held remote

until burner turns on. Hold the control button

again until burner turns off (see Figure 34).
TO LOCK

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.
TO UNLOCK

press both buttons together

on hand-held remote control until the light

stops flashing. The hand-held remote is now

unlocked.

ON
OFF
REMOTE

O

FF

P

ILOT

LO

IH

O

N

Figure 33 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

Selector Switch in Remote Position

Control
Knob

Flame Adjustment
Knob

Figure 34 - On/Off Hand-Held Remote

Control Unit (HRC101)

THERMOSTAT SERIES (MODEL
HRC201)

The hand-held remote can be operated using

either the manual mode (MANU) or thermo-

static mode (AUTO) (see Figure 35). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.

Figure 35 - Thermostat Hand-Held

Remote Control Unit (HRC201)

Locks
System to
Prevent
Accidental
Ignition

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns Hand-
Held Remote
On or Off and
Allows You
to Choose
the Manual
Setting

Selects AUTO
Mode

°C/°F Mode
Button

Turns
Burners
On or Off

Increases or
Decreases Room
Temperature in
AUTO Mode

Digital
Display
Shows
Temperature
and Settings

Control
Button

Indicator
Light