Specifications, Wiring diagram, Service hints – Desa CCL3924PRA User Manual

Page 32: Technical service, Specifications wiring diagram technical service

Advertising
background image

www.desatech.com

111161-01H

3

SPECIFICATIONS

WIRING DIAGRAM

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Products’ Technical Service Department at

1-866-672-6040. When calling, please have your

model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ techni-

cal service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so,

contact your local propane/LP gas supplier.

Receiver

Black

On
Off

Remote

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

CCL3018PR and CCL3018PRA

• Rating (Variable): 16,000/30,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 8.0" W.C.

• Inlet Gas Pressure (in. of water):

Max - 14" W.C., Min* - 11" W.C.
CCL3018NR and CCL3018NRA

• Rating (Variable): 16,000/30,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Max - 10.5" W.C., Min* - 5" W.C.
CCL3024PR, CCL3924PRA and
CCL3939PR

• Rating (Variable): 20,000/39,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 8.0" W.C.

• Inlet Gas Pressure (in. of water):

Max - 14" W.C., Min* - 11" W.C.

CCL3024NR, CCL3924NRA and
CCL3939NR

• Rating (Variable): 20,000/39,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Max - 10.5" W.C., Min* - 5" W.C.
CCL3930PR and CCL3930PRA

• Rating (Variable): 20,000/39,000 Btu/Hr

• Type Gas: Propane/LP

• Ignition: Piezo

• Manifold Pressure: 8.0" W.C.

• Inlet Gas Pressure (in. of water):

Max - 14" W.C., Min* - 11" W.C.
CCL3930NR and CCL3930NRA

• Rating (Variable): 20,000/39,000 Btu/Hr

• Type Gas: Natural

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

Max - 10.5" W.C., Min* - 5" W.C.

* For the purpose of input adjustment