Service procedures – Desa Air Conditioner User Manual

Page 8

Advertising
background image

www.desatech.com

113893-01B

8

SERVICE PROCEDURES

WARNING: Never service

heater while it is plugged in,

connected to propane supply,

operating or hot. Severe burns

and electrical shock can occur.

MOTOR

1. With heater on its side, remove access panel.
2. Access ground screw through underside of

heater base. Remove ground screw. Disconnect

the green motor wire and the green power cord

wire from underside of shell (see Figure 5).

3. Remove two black wires from motor to ter-

minal board.

4. Carefully push motor wires through hole in

bottom of shell.

5. Remove screws holding motor mount to shell.

Use nut-driver (see Figure 5).

6. Carefully pull motor and fan out of shell.

IMPORTANT:

Be careful not to damage fan.

Do not set motor and fan down with the weight

resting on fan. This could damage fan pitch.

7. Use hex wrench to loosen setscrew which

holds fan to motor shaft.

8. Remove fan. Be careful not to damage the fan

blade pitch.

9. Use nut driver to remove two nuts that attach

motor to motor mount.

10. Discard old motor.
11. Attach motor to motor mount with two nuts.

Tighten nuts firmly.

12. Replace fan on motor shaft. Make sure set

screw contacts flat surface on motor shaft.

13. Tighten set screw firmly (40-50 inch-pounds

[46.08-57.60 kilogram-centimeters]).

14. Carefully route motor wires through hole in

shell. Place motor, motor mount and fan guard

into rear of heater shell, as shown in Figure 5.

15. Insert screws through heater shell and into

motor mount. Tighten screws firmly.

16. Turn heater on its side to access opening in

bottom of base. Connect green wires from

motor, transformer and power cord to heater

shell using ground nut.

17. Attach two black wires from motor to terminal

board (see Wiring Diagram, page 10, for cor-

rect locations).

18. Replace access panel.

Figure 5 - Removing Motor and Fan

Guard from Heater (Heater may vary

from illustration)

Screw

Screw

Motor and
Fan Guard

FAN

1. Remove motor, motor mount and fan (see

Motor, steps 1 through 8).

2. Clean fan using soft cloth moistened with

kerosene or solvent.

3. Dry fan thoroughly.
4. Replace fan on motor shaft. Make sure set-

screw is touching back of flat surface on motor

shaft (see Figure 6).

5. Place setscrew on flat of shaft. Tighten set-

screw firmly (40-50 inch-pounds [46.08-57.60

kilogram-centimeters]).

6. Place motor, motor mount and fan guard

into rear of heater shell (see Motor, steps 14

through 18).

Figure 6 - Fan, Motor Shaft and Setscrew

Location

Figure 7 - Fan Cross Section

Motor Shaft

Fan

Setscrew

Fan

Hub

Setscrew

Motor
Shaft

Advertising