Cleaning and maintenance, Inspecting burners, Continued – Desa EFS33NR EU User Manual

Page 19

Advertising
background image

107172-01G

19

19

For more information, visit www.desatech.com

For more information, visit www.desatech.com

CLEANING AND
MAINTENANCE

WARNING: Turn off fireplace and let cool before

cleaning.

CAUTION: You must keep control areas, burner,

and circulating air passageways of fireplace clean.
Inspect these areas of fireplace before each use.
Have fireplace inspected yearly by a qualified service
person. Fireplace may need more frequent cleaning
due to excessive lint from carpeting, bedding mate-
rial, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER
AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with
the gas. This provides a clean burning flame. Keep these holes clear
of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each
heating season. Blocked air holes will create soot. We recommend
that you clean the unit every three months during operation and have
heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot
assembly clean and free of dust and dirt. To clean these parts we
recommend using compressed air no greater than 30 PSI. Your local
computer store, hardware store, or home center may carry com-
pressed air in a can. You can use a vacuum cleaner in the blow
position. If using compressed air in a can, please follow the direc-
tions on the can. If you don't follow directions on the can, you could
damage the pilot assembly.

1.

Shut off the unit, including the pilot. Allow the unit to cool for
at least thirty minutes.

2.

Inspect burner, pilot, and primary air inlet holes on injector
holder for dust and dirt (see Figure 41).

3.

Blow air through the ports/slots and holes in the burner.

4.

Check the injector holder located at the end of the burner tube
again. Remove any large particles of dust, dirt, lint, or pet hair
with a soft cloth or vacuum cleaner nozzle.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, pages

14 and 15, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

Figure 41 - Injector Holder On Outlet Burner Tube

Burner
Tube

Injector Holder

Primary Air
Inlet Holes

Ports/Slots

Figure 42 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/Slots

INSPECTING BURNERS

Front Burner Flame Pattern (Cont.)

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole

Logs

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 42). With the unit off, lightly blow
air through the air inlet hole. You may blow through a drinking straw
if compressed air is not available.

Figure 39 - Correct Burner
Flame Pattern

Figure 40 - Incorrect Burner
Flame Pattern

Yellow Tipping At Top
of Blue Flame

INSPECTING BURNERS

Continued

Advertising
This manual is related to the following products: