Wiring diagram, Specifications, Technical service – Desa EFS33NR EU User Manual

Page 23: Replacement parts, Service hints

Advertising
background image

107172-01G

23

23

For more information, visit www.desatech.com

For more information, visit www.desatech.com

AUT

O

OF

F

ON

Thermopile

WIRING DIAGRAM

Note

: For proper operation of optional accessories, the wires from

the switch to the control must be connected exactly as shown.

SPECIFICATIONS

MODELS EFS33NR, EFS33NRA, VSGF33NR, and
VSGF33NRA

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

MODELS EFS33PR, EFS33PRA, VSGF33PR, and
VSGF33PRA

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products’ Technical
Service Department at 1-866-672-6040. When calling please have
your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web
site at

www.desatech.com.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA Heating Products’ Techni-
cal Service Department at 1-866-672-6040.

When calling DESA Heating Products, have ready

• your name and address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA Heating Products at 1-866-672-6040
for referral information.

When calling DESA Heating Products, have ready

• model number of your fireplace

• the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local
gas supplier.