Switches and controls, Mains connection, Locating the machine – Kemppi Kempomat 1701 User Manual

Page 4: Operation safety

Advertising
background image

© KEMPPI OY

4 – KEMPOMAT 1701, KEMPOMAT 2100 / 0531

4

8

3

2

1

7

9

5

6

1.4. Switches and controls

1

Main switch and pilot light

2

Overheat control lamp

3

Voltage selector

4

Polarity selector

5

I Return current dix connector

(coarser arc), only Kempomat 2100

6

II Return current dix connector

(softer arc)

7

Welding method selector (2-way/

spot or 4-sequence)

8

Wire feed rate adjustment

potentiometer

9

Timer potentiometer

1.5. Mains connection

The machine is supplied with the mains cable installed. The cable may be disconnected and the plug

installed only by an authorised electrician! See under “Maintenance”. The fuse rating and the cable

diameter are given in the chapter Technical data in the end of this document.

1.6. Locating the machine

Use the front panel handles to move the machine. Use ropes for lifting. Do not use a hook or a chain!

Place the machine on a horizontal, stable and clean base. Protect from hard rain and intensive sun-

shine. Ensure unhindered circulation of cooling air.

1.7. Operation safety

Please study these Operation safety instructions and respect them when installing, operating and

servicing the machine.
Welding arc and spatters
Welding arc hurts unprotected eyes. Be careful also with reflecting arc flash. Welding arc and spatter

burn unprotected skin. Use safety gloves and protective clothing.
Danger for fire or explosion
Pay attention to fire safety regulations. Remove flammable or explosive materials from welding place.

Always reserve sufficient fire-fighting equipment on welding place. Be prepared for hazards in special

welding jobs, eg. for the danger of fire or explosion when welding container type work pieces. Note!

Fire can break out from sparks even several hours after the welding work has been finished!
Mains voltage
Never take welding machine inside a work piece (eg. container or truck). Do not place welding

machine on a wet surface. Always check cables before operating the machine. Change defect cables

without delay. Defect cables may cause an injury or set out a fire. Connection cable must not be

compressed, it must not touch sharp edges or hot work pieces.
Welding power circuit
Isolate yourself by using proper protective clothing, do not wear wet clothing. Never work on a wet

surface or use defect cables. Do not put MIG-gun or welding cables on welding machine or on other

electric equipment. Do not press MIG-gun switch, if the gun is not directed towards a work piece.
Welding fumes
Take care that there is sufficient ventilation during welding. Take special safety precautions when

welding metals which contain lead, cadmium, zinc, mercury or beryllium.