Kleenmaid TBR351ANBRWH User Manual

Page 14

Advertising
background image

6-6 REFRIGERATING CYCLE

Troubleshooting Chart

Leakage Detection

Observe discharging point of refrigerant which may be in oil discharging part in compressor and hole of evaporator.

- 14 -

YES-

YES-

Whether Compressor
runs or not.

Whether frost
forms or not in
Evaporator.

Observe the discharging
amount of Refrigerant.

Inject Refrigerant to Compressor
and check cooling operation.

Clogged by dust.

Gas leakage.

Faulty
Compressor.

Moisture Clog.

Whether oil leaks or not.

Normal formed frost

Normal amount

No or much amount

(Check the leakage point)

Normal formed
frost in Evaporator

No frost
or forms
in inlet only

Check Compressor

PARTIAL

Freezer room and

Low flowing sound of

A little high

¥ A little Refrigerant

LEAKAGE

Refrigerator

Refrigerant is heard and

more than

¥

discharges.

don't get cold

frost forms in inlet only

ambient

¥ Normal cooling is possible

normally.

temperature.

¥

when injecting Refrigerant

¥

of regular amount.

WHOLE

Freezer room and

Flowing sound of Refrigerant

Equal to ambient

¥ No discharging of Refrigerant.

LEAKAGE

Refrigerator

is not heard and frost isn't

temperature.

¥ Normal cooling is possible

don't get cold

formed.

¥

when injecting Refrigerant

nornally.

¥

of regular amount.

PARTIAL

Freeze room and

Flowing sound of Refrigerant

A little high

¥ Normal discharging of

CLOG

Refrigerator

is heard and frost forms

more than

¥

refrigerant.

don't get cold

in inlet only.

ambient

¥ The capillary tube is faulty.

normally.

temperature.

WHOLE

Freezer room and

Flowing sound of Refrigerant

Equal to ambient

¥ Normal discharging of

CLOG

Refrigerator

is not heard and frost isn't

temperature.

¥

Refrigerant.

don't get cold.

formed.

MOISTURE

Cooling operation

Flowing sound of Refrigerant

Low than

¥ Cooling operation restarts

CLOG

stops periodically.

is not heard and frost melts.

ambient

¥

when heating the inlet of

temperature

¥

capillary tube.

COMP-

Freezer room and

Low flowing sound of

A little high

¥ The pressure of high

RESSION

Refrigerator

Refrigerant is heard and

than ambient

¥

pressure part in

don't get cold.

frost forms in inlet only.

temperature.

¥

compressor is low.

NO COMP-

No compressing

Flowing sound of Refrigerant

Equal to ambient

¥ No pressure of high pressure

RESSION

operation.

is not heard and no frost.

temperature.

¥

part in compressor.

CAUSE

TEMPERATURE

OF THE

COMPRESSOR

REMARKS

STATE OF

THE SET

STATE OF THE

EVAPORATOR

LEAKAGE

CLOGGED

BY

DUST

DEFECTIVE

COMPRESSION

Advertising