Installation

9

506066

Installing the Dryer

Step 1: Position and Level the Dryer

For further assistance refer to section on Location
Requirements

.

Install dryer before washer. This allows room for

attaching exhaust duct.
Place the dryer in position, and adjust the legs until the

dryer is level from side to side and front to back.

Figure 3

Step 2: Connect Dryer Exhaust System

For further assistance refer to sections on Location
Requirements

and Dryer Exhaust Requirements.

DO NOT use plastic or thin foil ducting.

Locate dryer so exhaust duct is as short as possible.

Be certain old ducts are cleaned before installing

your new dryer.

Use 10.2 cm (4 inch) diameter rigid or flexible

metal duct.

The male end of each section of duct must point

away from the dryer.

Use as few elbows as possible.

Use duct tape or pop-rivets on all duct joints.

Ductwork that runs through unheated areas must

be insulated to help reduce condensation and lint

build-up on pipe walls.

Install backdraft dampers in multi-dryer

installations.

IMPORTANT: Failure to exhaust dryer properly
will void warranty.

Figure 4

NOTE: Venting materials are not supplied with the
dryer (obtain locally).

D669I

1

Dryer Base

2

Level

3

Leveling Leg

D669I

D259I

1

2

3

D314I

D315I

A clothes dryer produces combustible lint.
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.

W116

WARNING

DO

DON’T

Advertising