Installation

506066

20

Location Requirements

Select a location with a solid floor. Dryers installed in

residential garages must be elevated 46 cm (18 inches)

above the floor.
No other fuel burning appliance should be installed in

the same closet with the dryer.
The dryer must not be installed or stored in an area

where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer

with a 1/4 inch driver. All four legs must rest firmly on

the floor so the weight of the dryer is evenly

distributed. The dryer must not rock.
The dryer needs sufficient clearance and an adequate

air supply for proper operation and ventilation, and for

easier installation and servicing. (Minimum clearances

are shown in Figure 13.)

Figure 13

** NOTE: For new installations, locate top of wall vent 106.7 cm (42 inches) above floor to make venting easier to

connect.

D317I

1

Closet Door

3

Outer Wall of Enclosure

2

Centered Air Openings
(Two openings minimum)

B

A

C

D

A

E

3

FRONT VIEW

(w/o Closet Door)

Area

Description

Free Standing/Alcove

Installation

Closet Installation

A

Dryer sides and rear clearance

0 cm (0 in.)

0 cm (0 in.)

B

Dryer top clearance

30.5 cm (12 in.)

30.5 cm (12 in.)

C

Dryer front clearance

Not Applicable

5.1 cm (2 in.)

D

Exhaust duct clearance to combustible
material

5.1 cm (2 in.)

5.1 cm (2 in.)

E

Weather hood to ground clearance

30.5 cm (12 in.)

30.5 cm (12 in.)

F

Distance from floor or ceiling to hole
edge

Not Applicable

7.6 cm (3 in.)

SIDE VIEW

A

FRONT VIEW

(Closet Door)

**106.7 cm

(42 in.)

F

F

1

2 (G)

Advertising