Installation

506066

22

Exhaust Direction

The dryer can be exhausted to the outdoors through the

back, left, right or bottom of the dryer. EXCEPTION:
Gas dryers cannot be vented out the left side
because of the burner housing.

Dryer is shipped from factory ready for rear exhaust;
no kits required

.

Exhausting the dryer through sides or bottom can be

accomplished by installing Directional Exhaust Kit,

528P3, available as optional equipment at extra cost.

IMPORTANT: Do not block the airflow at the
bottom of the dryer’s front panel with laundry,
rugs, etc. Blockage will decrease airflow through
the dryer, thus reducing the efficiency of the dryer.

Figure 15

D328IE0A

D328IE0A

528P3 DIRECTIONAL EXHAUST KIT

Number of

90° Elbows

Weather Hood Type

Recommended

Use Only for Short Run Installations

Maximum length of 10.2 cm (4 in.) diameter rigid metal duct.

0

19.8 m (65 feet)

16.8 m (55 feet)

1

16.8 m (55 feet)

14.3 m (47 feet)

2

14.3 m (47 feet)

12.5 m (41 feet)

3

11.0 m (36 feet)

9.1 m (30 feet)

4

8.5 m (28 feet)

6.7 m (22 feet)

Maximum length of 10.2 cm (4 in.) diameter flexible metal duct.

0

13.7 m (45 feet)

10.7 m (35 feet)

1

10.7 m (35 feet)

8.2 m (27 feet)

2

9.1 m (30 feet)

6.4 m (21 feet)

3

7.6 m (25 feet)

5.2 m (17 feet)

4

6.1 m (20 feet)

4.5 m (15 feet)

NOTE: Deduct 1.8 m (6 feet) for each additional elbow.

Table 3

10.2 cm

(4 in.)

10.2 cm

(4 in.)

D673I

6.35 cm

(2-1/2 in.)

D802I