6. In case any large clumps of dust have now

been pushed into the burner repeat steps 3 and

4, page 21.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figure 39). With the unit

off, lightly blow air through the air inlet hole. You

may blow through a drinking straw if compressed

air is not available.

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs, page 16, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

Figure 39 - Pilot Inlet Air Hole

Burner
Tube

Pilot
Assembly

Pilot Air
Inlet Hole

Ports/
Slots

CLEANING AND

MAINTENANCE

Continued

AUTO

OFF

ON

Thermopile

WIRING DIAGRAM

Note:

For proper operation of optional accessories,

the wires from the switch to the control must be

connected exactly as shown.

SPECIFICATIONS

Models EFS33NRB and VSGF33NRB
Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)
Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

Models EFS33PRB and VSGF33PRB
Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)
Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment