Product identification, Safety information – Desa EFS33PRB User Manual

Page 4

Advertising
background image

www.desatech.com

113132-01B

4

SAFETY INFORMATION

Continued

1. This appliance is only for use with the type of

gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s) in-

side any structure. Locate propane/LP supply

tank(s) outdoors (propane/LP units only).

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use

any phone in your building

• immediately call your gas supplier from a

neighborʼs phone. Follow the gas supplierʼs

instructions

• if you cannot reach your gas supplier, call

the fire department

4. This fireplace shall not be installed in a bed-

room or bathroom.

5. Do not use this fireplace as a wood-burning

fireplace. Use only the logs provided with the

fireplace.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite, or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. To prevent the creation of soot, follow the

instructions in Cleaning and Maintenance,

page 21.

8. Before using furniture polish, wax, carpet

cleaner, or similar products, turn heater off.

If heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

9. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS shuts down the fireplace if enough fresh

air is not available. See Air for Combustion and

Ventilation, page 5. If fireplace keeps shutting

off, see Troubleshooting, page 23.

10. Do not run fireplace

• where flammable liquids or vapors are used

or stored

• under dusty conditions

11. Do not use this fireplace to cook food or burn

paper or other objects.

12. Do not use fireplace if any part has been exposed

to or under water. Immediately call a qualified

service technician to inspect the fireplace and to

replace any part of the control system and any

gas control which has been under water.

13. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

14. Turn fireplace off and let cool before servicing.

Only a qualified service person should service

and repair fireplace.

15. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

16. To prevent performance problems in

propane/LP units, do not use propane/LP

fuel tanks of less than 100 lbs. capacity

(propane/LP units only).

17. Provide adequate clearances around air

openings.

Optional Remote
Control

PRODUCT

IDENTIFICATION

Figure 1 - Log Base Assembly

(VSGF33NRB Shown)

Front
Log

Rear Log

Middle Log

Base Assembly

Front
Burner

Piezo
Ignitor

Rear
Burner

Optional
Blower
Assembly
(Not
Included)

Top Louver
Assembly

Fireplace
Hood

Bottom
Louver
Assembly

Screen
Assembly

Top Outer Casing

Firebox
Support

Figure 2 - Fireplace (VSGF33NRB Shown)

Advertising