Replacement parts, Technical service, Wiring diagram – Desa (F)SDVBNC User Manual

Page 33: Service hints

Advertising
background image

107304

For more information, visit www.desatech.com

For more information, visit www.desatech.com

33

33

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• burner system will not produce specified heat

• propane/LP gas supply might be low (propane/LP units only)

If you feel your gas pressure is too low, contact your local natural
or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International’s Technical
Service Department at 1-866-672-6040.

You can also visit DESA International’s technical service web site
at

www.desatech.com

.

REPLACEMENT PARTS

Figure 65 - Blower Wiring Diagram for Thermostat-Controlled
Models

WIRING DIAGRAM

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

Note:

Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply
original replacement part(s), call DESA International’s Technical
Service Department at 1-866-672-6040.

When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your burner system and stove
• how burner system or stove was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can not supply original
replacement part(s), call DESA International at 1-866-672-6040 for
referral information.

When calling DESA International, have ready
• model number of your burner system and stove
• the replacement part number

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

REPLACEMENT PARTS

Parts Under Warranty

Parts Not Under Warranty

TECHNICAL SERVICE

WIRING DIAGRAM

SERVICE HINTS