Operating fireplace, Warning, Notice – Desa CGF280PT User Manual

Page 24: Lighting instructions, Variable manually controlled model, Continued

Advertising
background image

24

102665

IGNITOR

LIGHTING INSTRUCTIONS

Figure 28 - Control Knob and Ignitor Button Location

Figure 29 - Pilot

WARNING ICON

G 001

WARNING

You must operate this fireplace with the fireplace screen in place.
Make sure fireplace screen is installed before running fireplace.

NOTICE

During initial operation of new fireplace, burning logs will give off
a paper-burning smell. Orange flame will also be present. Open
window to vent smell. Operate fireplace on HI position to burn off
odor. This will only last a few hours.

1. STOP! Read the safety information on page 23.
2. Make sure manual shutoff valve is fully open.

3. Turn control knob clockwise

Clockwise

to the OFF position.

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the

floor. If you smell gas, STOP! Follow “B” in the safety information above. If you
don’t smell gas, go to the next step.

5. Slightly depress and turn control knob counterclockwise

C-clockwise

to the PILOT

position. Press in control knob for five (5) seconds (see Figure 28, above).

Note:

If running fireplace for first time, there will be air in gas line. You may

need to press in control knob for 30 seconds or longer. This will allow air to
bleed from the gas system.

6. Continue pressing control knob in. Press and release ignitor button. This will light

pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service person or gas supplier

for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure
, page 25.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

• If control knob does not pop out when released, contact a qualified service

person or gas supplier for repairs.

Thermocouple

Ignitor Electrode

Pilot Burner

Ignitor Button

Control Knob

OPERATING

FIREPLACE

Variable Manually

Controlled Model

Continued

8. Slightly depress and turn control knob counterclockwise

C-clockwise

to the HIGH

position. Both burners should light. Set control knob to either HIGH or LOW.

Advertising