Trouble- shooting, Warning – Desa CGF280PT User Manual

Page 30

Advertising
background image

30

102665

TROUBLE-

SHOOTING

Continued

WARNING ICON

G 001

WARNING

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating fireplace where impurities in air exist may create odors.

Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new
carpet or textiles, etc., create fumes. These fumes may mix with combustion air and
create odors. These odors will disappear over time.

POSSIBLE
CAUSE

1. Metal expanding while

heating or contracting
while cooling

1. Fireplace burning va-

pors from paint, hair
spray, glues, cleaners,
chemicals, new carpet,
etc. (See

IMPORTANT

statement above)

2. Gas leak.

See Warn-

ing statement above

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak.

See Warn-

ing statement above

2. Control valve defective

1. Foreign matter be-

tween control valve
and burner

2. Gas leak.

See Warn-

ing statement above

1. Not enough combus-

tion/ventilation air

OBSERVED
PROBLEM

Fireplace produces a
clicking/ticking noise
just after burners are
lit or shut off

Fireplace produces
unwanted odors

Fireplace shuts off in
use (ODS operates)

Gas odor even when
control knob is in OFF
position

Gas odor during
combustion

Moisture/condensation
noticed on windows

REMEDY

1. This is common with most

fireplaces. If noise is
excessive, contact quali-
fied service person

1. Open window and venti-

late room. Stop using odor
causing products while
fireplace is running

2. Locate and correct all

leaks (see Checking Gas
Connections
, page 18)

1. Open window and/or door

for ventilation

2. Contact local natural gas

company

3. Clean ODS/pilot (see

Cleaning and Mainte-
nance
, page 27)

1. Locate and correct all

leaks (see Checking Gas
Connections
, page 18)

2. Replace control valve

1. Take apart gas tubing and

remove foreign matter

2. Locate and correct all

leaks (see Checking Gas
Connections
, page 18)

1. Refer to Air for Combus-

tion and Ventilation
requirements (page 6)

Advertising
This manual is related to the following products: