Maytag UXT2036AAB Dimension Guide User Manual

Page 2

Advertising
background image

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10133060

03-26-10

Page 2 of 2

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
7" (17.8 cm) Vent System

Vent Piece

7" (17.8 cm) Round

45° elbow 2.5

ft

(0.8 m)

90° elbow 5.0

ft

(1.5 m)

7" (17.8 cm)

0.0 ft

wall cap

(0.0 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 7" (17.8 cm)

(1.4 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 7" (17.8 cm) 90° elbow

(1.5 m)

7" (17.8 cm) to 3

¹⁄₄" x 10"

9.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(2.7 m)

Example vent system

Maximum Length

= 26 ft (7.9 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

Length of 7" (17.8 cm) system

= 13.0 ft (3.9 m)

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

Advertising