Specifications wiring diagram, Technical service – Desa B50G User Manual

Page 12

Advertising
background image

12

102016

Blade

Rotor

.003"/.004" Gap
Measured With
Feeler Gauge

Gap Adjusting Screw

Sandpaper

Gap Adjusting Screw

Figure 18 - Sanding Rotor

Figure 17 - Gap Adjusting Screw Locations

(Pump Rotor, continued)

10. Install blades, pump plate, air

filters, and filter end cover.

11. Replace fan guard and upper

shell.

12. Adjust pump pressure (see

page 11).

Note:

If rotor is still binding, pro-

ceed as follows.

13. Perform steps 1 through 6 (see

page 12).

14. Place fine grade sandpaper

(600 grit) on flat surface. Sand
rotor lightly in “figure 8” mo-
tion four times (see Figure 18).

15. Reinstall insert and rotor.
16. Perform steps 10 through 12

above.

Output Rating (Btu/Hr.)

50,000

Fuel

Use Only Kerosene

or No. 1 Fuel Oil

Fuel Tank Capacity (U.S. Gal.)

4.0

Fuel Consumption (Gal. Per Hr.)

.40

Electric Requirements

120 V/60 Hz

Amperage (Normal Run)

2.0

Motor RPM

1725

Hot Air Output (CFM)

175

Air Pump Pressure (PSI)

3.4

Shipping Weight (Approximate Pounds)

35

Heater Weight Without Fuel (Approximate Pounds)

30

SPECIFICATIONS

WIRING

DIAGRAM

White

Black

Blue

Green

Power Plug
120V 60HZ

Photocell

Spark Plug

Ignitor

Flame

Out

Control

B

Reset

Button

R

Red

Blue

White

White

White

White

Red

Red

Green

Terminal

Board

Motor

Figure 19 - Wiring Diagram

You may have further questions about operation or troubleshooting. If so, contact
DESA International's Technical Service Dept. at 1-800-323-5190.