Product identification, Unpacking, Theory of operation – Desa B50G User Manual

Page 4

Advertising
background image

4

102016

PRODUCT

IDENTIFICATION

35/50/70,000 BTU/HR DOMESTIC

PFA/PV 042

Handle

Fuel Cap

Lower Shell

Power Cord

Side Cover

Fuel Tank

Hot Air Outlet

Air Filter
End Cover

Fan Guard

Upper Shell

Flame-Out Control
Reset Button

Figure 1 - Models B50G and REM50B

1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If heater is damaged, promptly inform

dealer where you bought heater.

UNPACKING

The Fuel System:

The air pump forces air through the air line. The air is then

pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A fine mist of fuel is sprayed into the combustion chamber.

The Air System:

The motor turns the fan. The fan pushes air into and around

the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System:

The electronic ignitor sends voltage to the spark plug.

The spark plug ignites the fuel and air mixture.

The Flame-Out Control System:

This system causes the heater to shut down

if the flame goes out.

THEORY OF

OPERATION

THEORY CUTAWAY

PFA/OV 003

Combustion
Chamber

Spark
Plug

Burner
Head

Fan

Motor

Air Pump

Air Intake
Filter

Cool
Air
In

Air
Output
Filter

Air Line
To Burner

Electronic
Ignitor

Fuel
Filter

Nozzle

Fuel
Tank

Clean
Heated
Air Out

Air For Fuel
System

Air For Combustion
And Heating

Fuel

Figure 2 - Cross Section Operational View

Advertising