WARNING

!

Upper Shell Removal

1. Remove screws along each side of

heater using 5/16" nut-driver. These
screws attach upper and lower
shells together.

2. Lift upper shell off.
3. Remove fan guard.

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

Air Output, Air Intake, and
Lint Filters

1. Remove upper shell (see above).
2. Remove filter end cover screws

using 5/16" nut-driver.

3. Remove filter end cover.
4. Replace air output and lint filters.
5. Wash or replace air intake filter

(see Preventative Maintenance
Schedule, page 7).

6. Replace filter end cover.
7. Replace fan guard and upper shell.

IMPORTANT:

Do not oil filters.

Upper
Shell

Fan

IMPORTANT:

Remove fan from

motor shaft before removing motor
from heater. The weight of the motor
resting on the fan could damage the
fan pitch.

1. Remove upper shell (see above).
2. Use 1/8" allen wrench to loosen

set-screw which holds fan to motor
shaft.

3. Slip fan off motor shaft.
4. Clean fan using soft cloth mois-

tened with kerosene or solvent.

5. Dry fan thoroughly.
6. Replace fan on motor shaft. Place

fan hub flush with end of motor
shaft (see Figure 5).

7. Place setscrew on flat of shaft.

Tighten setscrew firmly (40-50
inch-pounds).

8. Replace fan guard and upper shell.

Figure 4 - Upper Shell Removal

Fan
Guard

Lint Filter

Air Output
Filter

Fan
Guard

Filter End
Cover

Air Intake
Filter

Figure 6 - Air Output, Air Intake

Figure 5 - Fan Cross Section

Flush

Motor

Fan

Setscrew

Motor
Shaft

Advertising