Specifications

25

Environmental

Table 14. Environmental specifications

Operating temperature range

0 to 50 °C

Storage temperature range

-40 to 85 °C

Humidity

0 to 90% non-condensing

Mechanical

Table 15. Mechanical specifications

Dimensions

127 mm (L) x 88.9 mm (W) x 35.56 (H)

Main connector and pin out

Table 16. Main connector specifications

Connector type

Screw terminal

Wire gauge range

16 AWG to 30 AWG

Pin

Signal Name

Pin

Signal Name

1

VOUT0

29

VOUT1

2

IOUT0

30

IOUT1

3

VOUT2

31

VOUT3

4

IOUT2

32

IOUT3

5

AGND

33

AGND

6

NC

34

NC

7

NC

35

NC

8

NC

36

NC

9

NC

37

NC

10

AGND

38

AGND

11

NC

39

NC

12

NC

40

NC

13

NC

41

NC

14

NC

42

NC

15

AGND

43

AGND

16

NC

44

NC

17

NC

45

NC

18

NC

46

NC

19

NC

47

NC

20

AGND

48

AGND

21

DIO0

49

SYNCLD

22

DIO1

50

DGND

23

DIO2

51

ITEST

24

DIO3

52

CTR

25

DIO4

53

DGND

26

DIO5

54

DIO CTL

27

DIO6

55

DGND

28

DIO7

56

+5V

Advertising
This manual is related to the following products: