Chapter 4

Printer Modes

226/426 User’s Guide

19

command. This response appears in conjunction with the >STOCK OUT< error and a
printer configured with the “^D581)2” Finish Label command.


4.2.2.12

>CATCH TRAY FULL< (20)

The “>CATCH TRAY FULL<” response is generated when the optional Catch Tray has
reached its capacity while in text or verbose response modes. If the printer is configured for
byte responses, the code ASCII 0x20 is issued from the printer in response to an enquiry
command.


4.2.2.13

>SCRIPT ERROR< (30)

The “>SCRIPT ERROR<” response is generated when a script contains an error and cannot
be processed while in text and verbose response sets. If the printer is configured for byte
responses, the code ASCII 0x30 will be issued from the printer in response to an enquiry
command.


4.2.2.14

>INVALID PARAMETER< (31)

This error response indicates that a received command contains an invalid parameter or
illegal structure while in text and verbose response sets. If the printer is configured for byte
responses, the code ASCII 0x31 will be issued from the printer in response to an enquiry
command.


4.2.2.15

>PARSER ERROR< (32)

The “>PARSER ERROR<” indicates that the printer has detected an internal error with the
parser while in text and verbose response sets. If the printer is configured for byte
responses, the code ASCII 0x32 will be issued from the printer in response to an enquiry
command.


4.2.2.16

>COMM ERROR< (40)

The “>COMM ERROR<” indicates that the printer has detected a communication error while
in text or verbose response modes. If the printer is configured for byte responses, the code
ASCII 0x40 is issued from the printer in response to an enquiry command. This error
response is generated if the serial communication timeout period of 10 seconds plus 100
times the transfer has occurred.


4.2.2.17

>FLASH ERROR< (51)

The “>FLASH ERROR<” indicates that an error has occurred with the flash memory while in
text and verbose response sets. The printer power should be cycled in the event that this
error message has been received. If the printer is configured for byte responses, the code
ASCII 0x51 will be issued from the printer in response to an enquiry command.