8
• Maximum Cable Distance :
Configuration
Max. Distance
RS232
15m(50ft)
RS422/485
1220m (4000ft)
Multi-mode Fiber
2km
Single-mode Fiber
20km ∗
*
Any other distance is upon request.
• Fiber Cable: 50/125, 62.5/125, or 100/140
µ
m multi-mode
8.3/125, 8.7/125, 9/125 or 10/125
µ
m single-mode
Bidi-SC 1310 nm, 1550 nm
• Data Transfer Rate : up to 460.8Kbps
• LED : PWR , FX, DATA
• Power Requirement: 1 A@+5 VDC
• Ambient Temperature: -10 to 60°C(Industrial)
0 to 50°C (Commercial)
• Humidity : 5% to 90%
• Dimensions: 26.2(H) × 70.3(W) × 94(D) mm
• Complies with CE Mark