...or with the Teach-in procedure

Adjust detect point

Place object at position 

Press T2 until »d« is shown

Current measu-
ring value

Press T2 until »End« is

shown

Adjust window mode

Place object at position 

Press T2 until »d« is shown

Place object at position 

Current measu-
ring value

Press T2 until »End« is

shown

Current measu-
ring value

Adjust two-way reflectiv

barrier

Place reflector at position 

Set NOC/NCC

Press T2 until »d« is shown

Current measu-
ring value

Press T2 until countdown

passed from »- 8 -« to »- 0 -«

and NOC or NCC symbol is

displayed

Press T2 until countdown

passed from »- 8 -« to »- 0 -«

and »End« is displayed

To change output function

press T2

Press T1 and T2 simultane-

ously until »End« is dis

played

Symbol
NOC or NCC

Symbol
NOC or NCC

Normal mode operation

T1 + T2

T1



T2



T1 + T2



Press T1 and T2 simultaneously for about 13 s
until »Add« is shown in the LED-display

T1 + T2

T2

T1

Start here







T2



T1



T1 + T2



Ready



»C01«: Display
bright

»C02«: Display dim-
med

»C03«: Display off

To optimize multi-
plex speed the hig-
hest sensor address
may be set.

Setting range »01«
to »10«

»F00«: no filter

»F01«: standard fil-
ter

»F02«: averaging fil-
ter

»F03«: foreground
filter

»F04«: background
filter

Defines the strength
of the chosen filter.

»P00«: weak filter
up to

»P09«: strong filter

Affects the size of
the detection zone.

»E01«: high

»E02«: standard

»E03«: slight

Minimum value:
blind zone

Maximum value: ne-
arwindow limit - 1

Low power mode

Measurement filter

Filter strength

Foreground
suppression

Multiplex mode

device addressing

Multiplex mode
highest address

»00«: synchronisati-
on

»01« to »10«: sensor
address for multi-
plex mode

»oFF«: synchronisati-
on deactivated

Minimum value: sen-
sor-distant window
margin

Maximum value: 999
mm for mic+
25/...,mic+35/...,
999 cm for mic+
130/...,mic+340/...,
mic+600/...

Measurement range

Calibration

display

Detection zone

sensitivity

Put plane reflector
vertically disposed in
front of sensor: in
an exact distance of
250 mm for mic+
25... and mic+35...
and 900 mm for all
other typs.
Adjust display to
250 mm or 900 mm.
Confirm calibration
with T1 + T2.

T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













T1 + T2

T1

T2

T1 + T2

T2

T1













Delay in seconds
between the detec-
tion of an object
and the output of
the measured dis-
tance in case of ob-
ject approach (beha-
ves as on-delay).

"00": 0 s (no delay)
up to

"20": 20 s response
time

Response time

T1 + T2

T1

T2

T1 + T2

T2

T1















Note
Changes in the Add-on
menu may impair the
sensor function.
A6, A7, A8 , A10 , A11,
A12 have influence on
the response time of
the sensor.

Hysteresis

switched output

Minimum value:
»001«

Maximum value: dif-
ference between
maximum range and
detect point - 1

During window
mode operation hys-
teresis influences
both detect points.

T1 + T2

T1

T2

T1 + T2

T2

T1













Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)

Teach-in swítched output

Key lock and factory setting

Activate/deactivate

TouchControl

Reset to factory set-

ting

Turn supply voltage

OFF

While pressing T1

turn supply voltage

ON until »on« or

»off« is displayed

Turn supply voltage

OFF

Turn supply voltage

ON while pressing T1

and keep it pressed

for ca. 15 s until

»rESEt« has passed

through the display

To activate or

deactivate press T1

»on« or
»off«

To activate or

deactivate press T1

»on« or
»off«

Normal mode operation