Microsonic lcs+340/F User Manual

Page 2

Advertising
background image

Technical data

blind zone

operating range
maximum range

angle of beam spread

0 to 350 mm
3,400 mm

0 to 600 mm
6,000 mm

5,000 mm
see »detection zones«

8,000 mm
see »detection zones«

transducer frequency

resolution

reproducibility

detection zones

for different objects:

The dark grey areas represent the zone

where it is easy to recognise the normal

reflector (round bar). This indicates the typical

operating range of the sensors. The light

grey areas represent the zone where a

good reflector – for instance a

plate – can still be regognised.. The

requirement here is for an optimum

alignment to the sensor. It is not

possible to evaluate ultrasonic

reflections outside this area.

120 kHz
0.18 mm

80 kHz
0.18 mm

± 0.15 %

± 0.15 %

accuracy

operating voltage U

B

voltage ripple

±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)

±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)

9 V to 30 V DC, reverse polarity protection
±10 %

9 V to 30 V DC, reverse polarity protection
±10 %

no-load current consumption

housing

class of protection per EN 60 529

≤ 60 mA
PBT, Polyester; ultrasonic transducer:

≤ 60 mA
PBT, Polyester; ultrasonic transducer:

polyurethane foam, epoxy resin with glass content
IP 67

polyurethane foam, epoxy resin with glass content
IP 67

type of connection

controls

programmable

5-pin M12 circular plug, PBT
2 push-buttons

5-pin M12 circular plug,. PBT
2 push-buttons

• Teach-in via push-buttons
• LCA-2 with LinkControl

• Teach-in via push-buttons
• LCA-2 with LinkControl

indicators

synchronisation

operating temperature

storage temperature

LED yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors

LED yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors

-25°C to +70°C
-40°C to +85°C

-25°C to +70°C
-40°C to +85°C

weight

switching hysteresis

1)

switching frequency

1)

response time

1)

180 g
50 mm

240 g
100 mm

4 Hz
172 ms

3 Hz
240 ms

time delay before availability

1)

norm conformity

order no.

< 380 ms
EN 60947-5-2

< 450 ms
EN 60947-5-2

lcs+340/F

lcs+600/F

switched output

1) Can be programmed with LinkControl and IO-Link

Push-Pull, U

B

-3 V, -U

B

+3 V, I

max

= 100 mA

NOC/NCC adjustable, short-circuit-proof

Push-Pull, U

B

-3 V, -U

B

+3 V, I

max

= 100 mA

NOC/NCC adjustable, short-circuit-proof

+U

B

-U

B

F
Com

1
2
4
5
3

Push-Pull output in pnp circuit

U

+U

B

-U

B

F
Com

1
2
4
5
3

Push-Pull output in npn circuit

U

lcs+340...

lcs+600...

0 m

0.8 m

1.6 m

2.4 m

3.2 m

4 m

4.8 m

5.6 m

3.4 m

Plate

Round bar ø 27 mm

1.6 m

0.8 m

0 m

0.8 m

1.6 m

0 m

1.2 m

2.4 m

3.6 m

4.8 m

6 m

7.2 m

8.4 m

Plate

Round bar ø 27 mm

2.4 m

1.2 m

0 m

1.2 m

2.4 m


Fig. 4: Setting the detect point for different

directions of movement of the object



The sensor can be reset to its fac-
tory setting (see »Further set-
tings«).



Using the LinkControl adapter (op-
tional accessory) and the LinkCon-
trol software for Windows, all
Teach-in and additional sensor pa-
rameter settings can be optionally
undertaken.

microsonic GmbH | Hauert 16 | 44227 Dortmund | Germany | telephone +49 2 31 / 97 51 51-0 | telefax +49 2 31 / 97 51 51-51 | e-mail: [email protected] | www.microsonic.eu The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product fea-