2.2.5 FC-3G-EO-OE-36

The optical to electrical is always the upper row and the electrical to optical is
always the lower row.

Earth point:

For connection to internal earth bar in 19”

Upper BNC:

Electrical 3G/HD/SD-SDI outputs.

Lower BNC:

Electrical 3G/HD/SD-SDI inputs.

DIP 1 to 8:

Configures the Flashlink Compact II. See chapter 5 for more information.

(upper and lower)

Upper RS422: RJ45 connector for connection for Multicon Gyda.

Lower RS422: RJ45 connector for daisy chaining more Flashlink Compact II. This must be

terminated when not used.

Power A:

Main DC input connector. Standard 9pin DSUB. Pin 4 is positive voltage
and pin 1 is ground.

Power B:

Spare/redundancy DC input connector. Standard 9pin DSUB. Pin 4 is
positive voltage and pin 1 is ground.