5 module status 5.1 gpi alarm, Module status outputs, 5 module status – Nevion DA-SDI User Manual

Page 10: 1 gpi alarm – module status outputs

Advertising
background image

DA-SDI

Rev. H


nevion.com | 10

5 Module status

The status of the module can be monitored in three ways.

1. GYDA System Controller (optional).

2. GPI at the rear of the sub-rack.

3.

LED’s at the front of the sub-rack.

Of these three, the GPI and the LED’s are mounted on the module itself, whereas the
GYDA System Controller is a separate module giving detailed information on the card
status. The functions of the GPI and the LED’s are described in sections 5.1 and 5.2.
The GYDA controller is described in a separate user manual.

5.1 GPI ALARM

– Module Status Outputs

These outputs can be used for wiring up alarms for third party control systems. The
GPI outputs are open collector outputs, sinking to ground when an alarm is triggered.
The GPI connector is shown in Figure 8.

Electrical Maximums for GPI outputs

Max current: 100mA

Max voltage: 30V

DA-SDI module GPI pinning (Only supported by DA-SDI-C1 backplane):

Figure 8: GPI Outlet

Signal

Name

Pin #

Mode

Status

General error status for the module.

Pin 1

Open Collector

Rate

Rate SD

Pin 2

Open Collector

LOS

Los Of Signal

Pin 3

Open Collector

LOCK

Reclocker in Lock

Pin 4

Open Collector

Ground

0 volt pin

Pin 8

0V.