2 front panel - status monitoring – Nevion DA-SDI User Manual

Page 11

Advertising
background image

DA-SDI

Rev. H


nevion.com | 11

5.2 Front Panel - Status Monitoring

The status of the module can be easily monitored visually by the LED’s at the front of
the module. The LED’s are visible through the front panel as shown in Figure 9 below.

(Text not printed on the front panel).

Figure 9: Front panel indicator overview for DA-SDI.

The DA-

SDI has 4 LED’s each showing a status corresponding to the GPI pinning. The

position of the different LED’s is shown in Figure 9.

Diode\state

Red LED

Yellow LED

Green LED

No light

Status

Module is faulty

Module is OK
Module power is
OK

Module
has no
power

Rate

Rate not
detected

SD rate, non
270Mbps, found

SD 270Mbps rate
found

LOS

Loss of signal
No input signal.

LOS detection
de-activated
(EQM=off)

Input signal
present

LOCK

Re-clocker is out
of lock

Re-clocker
switched off

Re-clocker is in
lock on a
supported signal
format