Norsat 100W ATOM User Manual

Page 17

Advertising
background image

ATOM 100W

Revision 1.1

908236

17

908236_r1.1 - Operator Manual ATOM KU

100W.doc

Command

Param-Value

Pairs

Response Format

(enveloping <CR><LF> characters not shown)

getmute

None

ok value <mute_val>

where:

<mute_val> = output mute value, range 0-1 (0=unit not muted; 1=unit muted)

setmute value (0|1)

ok

resetfaults

None

ok

Table 2-3: Command Response Examples

Command

Response

getident

getident<CR>

<CR><LF>ok pn AMP-Ku100 swver 1.0.9_2 sn AMP-Ku100-30230 address 7 syn no<CR><LF>

getstatus

getstatus<CR>

<CR><LF>ok fault 0xC fwdpwr -38.7 revpwr -40.0 temp 38<CR><LF>

getmute

getmute<CR>

<CR><LF>ok value 0<CR><LF>

setmute

setmute value 1<CR>

<CR><LF>ok<CR><LF>

Resetfaults

resetfaults<CR>

<CR><LF>ok<CR><LF>