908236_r1.1 - Operator Manual ATOM KU

100W.doc

Section 2.6
G

ROUND

C

ONNECTION

The unit is supplied with a 10-32 screw and internal tooth lock washers for grounding purposes. It is
highly recommended that the unit be grounded according to national and local electrical codes before
use.

 

Section 2.7
I

NDICATORS

/

LED

S

There are three LEDs on the unit that provide status to the user.

Table 2-6: Indicators / LEDs

Pin

Color

Name

POWER

Green

On = Power on

Off – Power off

FAULT

Red

On = Internal voltage regulator fault, over-temperature
fault, or PLL phase lock fault

Off = No faults

TEMP

Red

On = Over-temperature fault

Off = No over-temperature fault

When power is first applied, an LED test will be performed and all LEDs will illuminate for 1 second.

The POWER LED will illuminate whenever power is applied to the unit.

The FAULT LED will illuminate when an internal regulator is not producing the proper voltage, the internal
temperature is too high, or the PLL has lost phase lock. The unit will be muted while the fault condition
exists.

The TEMP LED will illuminate when the internal temperature is too high. The unit will be muted while this
fault condition exists.

Section 2.8
P

HYSICAL

M

OUNTING

/C

OOLING

/W

ATER

-T

IGHTNESS

The unit is entirely watertight and suitable for outdoor operation. All joints are O-ring sealed. The
waveguide port J4 is not internally sealed, so the antenna feed must be sealed with a radome or window,
and all waveguide joints must be O-ring sealed if water-tightness is required.