- Serial command: gwwr 192 168 100 1 (Write Command)

- Serial command: gwrd (Read Command)

Step 4. Set up Subnet Mask

- Serial command: smwr 255 255 255 0 (Write Command)

- Serial command: smrd (Read Command)

Step 5. Set up Subnet Mask

- Serial command: smwr 255 255 255 0 (Write Command)

- Serial command: smrd (Read Command)

Step 6. Set up Mac address

- Serial command: macwr ff 11 dd 22 1 2 (Write Command)

- Serial command: macrd (Read Command)

Step 7. Set up PC IP

- Serial command: sendipwr 192 168 100 10 (Write Command)

- Serial command: sendiprd (Read Command)

In this step, you have to input IP of the computer which you’re using.

Step 8. Set up PC Port

- Serial command: sendportwr 4001 (Write Command)

- Serial command: sendportrd (Read Command)

B. PC parameters setup for Ethernet connection:

There are two steps to perform for PC parameters setup for Ethernet connection.

Step 9. Set up PC parameters

The BUC IP, BUC PORT, and PC PORT number should be entered into the Ethernet

parameters

boxes on BUC GUI window as shown in Fig. 16.

Step 10. Click OPEN