Norsat O3b 10W BUC User Manual

Page 22

Advertising
background image

© 2013 Norsat International Inc.

Page 22 of 26

Figure 16. PC parameters entry on BUC GUI window for Ethernet operation

If the Ethernet port is open, BUC GUI will show a serial number (SERIAL NO), and the LED color for

ETHERNET changes from red into green and Enable is marked as shown in Figure 16. BUC GUI

starts reading status information of the BUC periodically. And you can send control commands you

want to the BUC by clicking proper tabs such as MAX GAIN or SSPA ON or entering serial

commands into the serial command text box shown in Fig. 13.

5.2.5 BUC Turn-on/off Sequence.

After the user software is installed on your PC, the following sequence can be used to turn on the

BUC.

1) Connect one end of a RF cable with a WR28 waveguide adapter to WR28 RF port on the

BUC and the other end of the RF cable to the antenna or a dummy load.

2) Connect one end of an IF cable to N-type IF connector on the BUC and the other end of the

IF cable to the output of the IF source or modem.

3) Connect one end of a MS 12-wires cable to MS 12-pins connector on the BUC. And connect

two wires out of the other end of the MS 12-wires cable, which are dedicated to DC power,

to a power supply with +48V DC or a level specified in the specification sheet in Section 3.1,

and four wires for Ethernet connection or three wires for RS232 connection out of the other

end of the MS 12-wires cable to the modem or your PC, and two wires for external Mute

function to a separate power supply with +5V on. (Refer to Table 1 and Fig. 4 for connection

details)