Pacific Research Solutions PET-820 User Manual
Page 23
Pacific Research
PET-820 User Manual
Page 22
4.5.6
ARM DELAY
In applications where the PET-820 is used to monitor exit or entrance doors the ARM DELAY may be used to provide a
delay after the unit has received an arm command. This allows a person to exit a building before the unit is armed.
COMMAND CODE:
16
PROGRAM SYNTAX:
16 [Data] #
READ BACK SYNTAX:
16 #
WHERE:
Data = 000 to 255 seconds, 256 through 999 is invalid data and will abort the command
EXAMPLE:
16 30 # = Set the alarm delay for 30 seconds
DEFAULT:
15 seconds
4.5.7
COMMUNICATION DELAY BEFORE DIALING
This feature allows the user to delay for a time of 2 to 255 seconds before dialing in which to abort the transmission of an
alarm. Note that values of 0 and 1 entered into this command will generate a minimum of 2 seconds. The dial delay is also
used as a delay between each of the dial attempts.
COMMAND CODE:
17
PROGRAM SYNTAX:
17 [Data] #
READ BACK SYNTAX:
17 #
WHERE:
Data = 000 to 255 seconds, 256 through 999 is invalid data and will abort the command
EXAMPLE:
17 30 # = Sets the dial delay to 30 seconds
DEFAULT:
5 seconds
4.5.8
ALARM RELAY OUTPUT CUTOFF TIME
On alarm conditions that operates the relay, an automatic cutoff timer may be programmed to turn off the relay after the
cutoff time has elapsed. A "000" may be programmed for no alarm relay cutoff.
COMMAND CODE:
18
PROGRAM SYNTAX:
18 [Data] #
READ BACK SYNTAX:
18 #
WHERE:
Data = 000 to 255 minutes, 000 will disable the alarm relay cutoff function
256 through 999 is invalid data and will abort the command
EXAMPLE:
18 30 # = The alarm relay will turn off after 30 minutes
DEFAULT:
30 minutes
4.5.9
ALARM DELAY
Once an alarm condition has occurred, the alarm delay time may be programmed in order to allow the user adequate time to
locally disarm the unit. The unit will not attempt to establish communication or operate the relay until the alarm delay has
timed out.
COMMAND CODE:
19
PROGRAM SYNTAX:
19 [Data] #
READ BACK SYNTAX:
19 #
WHERE:
Data = 000 to 255 seconds, 000 will disable the alarm relay cutoff function
256 through 999 is invalid data and will abort the command
EXAMPLE:
19 45 # = Sets the alarm delay to 45 seconds
DEFAULT:
15 seconds