System configuration byte 1, System configuration byte 2, System configuration byte 3 – Pacific Research Solutions PET-820 User Manual
Page 73: System configuration byte 4
Pacific Research
PET-820 User Manual
Page 72
SYSTEM CONFIGURATION BYTE 1
BIT NO.
BYTE
ADDRESS
DEFAULT DESCRIPTION
7654321
0
1
0 NEW EEPROM FLAG
765432
1
0
2
2 LOCAL ARM/DISARM ENABLE
76543
2
10
4
0 LOOP 8 EXTERNAL ARM/DISARM CONTROL
7654
3
210
8
0 ENABLE DIAL PULSE
765
4
3210
16
0 PROGRAM COMMUNICATION SELECT, 2 BITS
76
5
43210
32
32
7
6
543210
64
0 ALARM COMMUNICATION SELECT, 2 BITS
7
6543210
128
128
TOTAL VALUE
162
SYSTEM CONFIGURATION BYTE 2
BIT NO.
BYTE
ADDER
DEFAULT DESCRIPTION
7654321
0
1
0 ARM/DISARM
765432
1
0
2
0 ALARM FLAG
76543
2
10
4
4 ERASE DISABLE, INTERNAL FUNCTION
7654
3
210
8
0 LOOP MONITOR ON/OFF
765
4
3210
16
0 RADIO INTERFACE ENABLE
76
5
43210
32
0 PULSING ALARM RELAY ENABLE
7
6
543210
64
0 SYSTEM STATUS ENABLE
7
6543210
128
0 N/A
TOTAL VALUE
004
SYSTEM CONFIGURATION BYTE 3
BIT NO.
BYTE
ADDER
DEFAULT DESCRIPTION
7654321
0
1
0 SYSTEM SIGN ON MESSAGE, FIRST 4 BITS
765432
1
0
2
2
76543
2
10
4
0
7654
3
210
8
0
765
4
3210
16
0 PASSWORD DISABLE FLAG
76
5
43210
32
0 ADC ENABLE
7
6
543210
64
64 ALARM MESSAGE DELAY SELECT, 2 BITS
7
6543210
128
0
TOTAL VALUE
066
SYSTEM CONFIGURATION BYTE 4
BIT NO.
BYTE
ADDER
DEFAULT DESCRIPTION
7654321
0
1
0 TELEPHONE DIRECTORY ENABLE
765432
1
0
2
0 N/A
76543
2
10
4
0 N/A
7654
3
210
8
0 N/A
765
4
3210
16
0 N/A
76
5
43210
32
0 N/A
7
6
543210
64
0 N/A
7
6543210
128
0 N/A
TOTAL VALUE
000